Isolator workstation - General 510.01
Isolator workstation is a facility forming a barrier between the product and the operators, including all necessary technical resources to ensure safety in case of accident.
It is suitable for handling sterile materials, as well as for working with highly active compounds. Depending on the degree and type of risk, it may operate, in terms of ambient pressure, in the negative pressure or positive pressure mode.
Another important parameter is the tightness class to ISO 10648-2. Standard isolators reach tightness class 4, 3 or 2 respectively. There is a possibility to create inert atmosphere inside the isolator, e.g. for work with substances sensitive to oxygen.
TECHNICAL DATA
Equipment designation |
---|
Isolator workstation |
Selecting class of cleanliness |
---|
according to EU /"A/", according to ISO 14 644 /"ISO 4,8/", with laminar flow |
according to EU /"C/", according to ISO 14 644 /"ISO 7/", with turbulent flow |
according to EU /"D/", according to ISO 14 644 /"ISO 8/", with turbulent flow |
In this category, the class of cleanliness and the type of flow in the chambers are selected. |
Sterilization by hydrogen peroxide vapour generator |
---|
Without Puriter H2O2 vapour generator |
External Puriter H2O2 vapour generator |
Integrated H2O2 vapour generator for the isolator |
In this category, you can select whether sterilization by hydrogen peroxide vapour generator is required. For more info see equipment catalogue sheet 570.01. |
Selecting type and size of glove flanges |
---|
Inlet round opening for gloves with a clamping diameter of 172 mm (7/") |
Inlet round opening for gloves with a clamping diameter of 190 mm (8/") |
Inlet oval opening for gloves with a clamping diameter of 190 mm (8/") |
In this category, you can select the type and size of flanges for sleeves. |
Glove holder |
---|
No, without glove holders |
Alternative options - upon agreement with the dealer |
Yes, the number of holders corresponds to the number of gloves |
It is used to hold gloves in the chamber. |
Selecting control panel location |
---|
Mobile external counter |
mounted on the inclined part of the upper structure over the chamber |
mounted on a supporting arm (swivel arm) |
In this category, there is a choice of three versions of control panel mounting. |
Selecting backup power source - UPS |
---|
No - Backup power source not required |
Yes - Backup power source required |
In this section it is selected whether the isolator will be equipped with a backup power source in case of power failure. |
Selecting doors and chamber sequence |
---|
Code specifying the order of ports and chambers |
In this section, the doors (for the transfer of material between the chambers) and the sequence of individual chambers are specified. This code is used to obtain a visual idea of the structure of the isolator. |