E-katalog skupiny BLOCK®
Circulating unit (CU) to be installed below suspended ceiling or onto movable box 04/D
Circulating units are used to supply filtered air to a workplace and to protect the product from ambient contamination.
The design of the circulating unit, together with suitable regulation, provides uniform airflow at the outlet under the unit, with the required speed in the range of 0.3 ÷ 0.45 m.s-1 (when air density ς = 1.2 kg.m3).
The protective effect is enhanced by attaching flexible or fixed screens along the perimeter of the unit.
When installing the circulating unit in areas without a defined class of cleanliness or in an environment with increased dust generation, a pre-filter is mounted at the suction inlet of the unit.
TECHNICAL DATA
Type |
---|
circulating unit (CU) to be installed below suspended ceiling or onto movable box |
A, B etc. - number of product change Change C - as of 03/2016 (fluid seal filters, touchscreen) |
CU size |
---|
CU dimensions 1250×625 mm |
CU dimensions 1250×1250 mm |
HEPA filter filtration class |
---|
H13 class filtration |
H14 class filtration |
U15 class filtration |
Suction design |
---|
upper suction |
Bottom suction from the room (with side structure) |
Suction via HVAC upper structure with side rectangular neck |
Suction via HVAC upper structure with upper round neck |
Suction via HVAC upper structure with upper square neck |
Pre-filter |
---|
without pre-filter |
with pre-filter |
Cooling |
---|
without cooling |
with cooling |
Outlet design |
---|
perforated metal sheet |
laminarizator |
Lighting |
---|
without lighting |
with fluorescent lighting |
with LED lighting tubes |
Lighting - only for the laminarizator version |
Control and regulation designs |
---|
touchscreen, automatic continuous regulation with feedback (allows control from COP) |
control panel with switches, manual continuous regulation without feedback |
one switch, manual continuous regulation without feedback - for movable laminar boxes only |
Material and surface finish |
---|
steel sheet class 11, hue RAL 9002, 5% extra charge |
steel sheet class 11, hue RAL 9016 |
stainless steel AISI 304 SB |
Screens |
---|
without screens |
flexible slat screens |
fixed screens |
flexible antistatic slat screens |
fixed antistatic screens |
Screen length |
---|
length of screens in mm (min. length of screens 250 mm) |
000 - if without screens |
Height of expanded-metal covering to the suspended ceiling |
---|
without covering |
height of covering (between upper edge of CU and suspended ceiling) must not be less than 200 mm |
Locations of holders of screens and additional covering |
---|
screens at side, front, side side |
screens along the whole perimeter of the unit |
screens at front, side, rear side |
screens at front and left side (front side is longer), same as rear and right side |
screens at front and right side (front side is longer), same as rear and left side |
screens at front (longer) side |
screens and covering not specified |
Atypical execution |
---|
Typical execution |
Atypical execution |
Typical execution 0 - clear choice from the options Atypical execution Q - Atypical design, which can not be clearly identified by means of code |