E-katalog skupiny BLOCK®
HPL sandwich panels 121.01/A
HPL partition panels represent one of the basic elements to construct clean workplaces and areas with maximum safety, sterility, hygiene, easy maintenance, sanitation, and - in particular - chemical resistance.
Their design is suitable especially for hospital environments, areas in pharmaceutical industry, electrotechnical industry, mechanical engineering industry, food industry, and chemical industry.
Due to the tight connection between the partition panels, spaces created between the panels, the floor and the ceiling are guaranteed to contain overpressure or underpressure in the room, which means that they meet the basic criteria for clean areas, for which these panels were specifically designed and proven.
TECHNICAL DATA
Panel type |
---|
basic partition panel |
Panel thickness |
---|
60 mm |
80 mm |
100 mm |
120 mm |
Panel width W |
---|
1190 mm |
560 mm |
W - width in mm according to dimensional range 560 mm, 1190 mm. It is possible to order atypical panel dimensions: min. dimension 300 mm, max. dimension 1190 mm. |
Panel height H |
---|
2550 mm |
2750 mm |
3050 mm |
Height according to standard dimensional range 2550, 2750, 3050 mm. Preferred dimensions 2550, 2750, 3050 mm. Min. dimension 300 mm, max. dimension 3500 mm. |
Side end |
---|
groove - tongue |
tongue - tongue |
groove - groove |
Bottom end |
---|
basic (tongue) |
basic+reinforcement |
clasic (straight) |
clasic+reinforcement |
groove |
Upper end |
---|
no upper bend (high panels) |
basic (tongue) |
basic with reinforcement (tongue) |
clasic (straight) |
groove |
Side reinforcement |
---|
without reinforced reinforcement |
reinforced reinforcement |
For right and left reinforcement, it is necessary to keep the orientation according to the diagram of the side ends. |
Number of cable glands |
---|
no cable gland |
2 pcs (1 pc 85 mm from the left - 1 pc 85 mm from the right) |
cable glands from the left, cable glands from the right |
Example of designation in the case of multiple cable glands: Orientation and number of cable glands are specified. The first cable gland is 85 mm from the edge. Other cable glands are located 100 mm apart from each other as standard.3;2 – Total of 5 pcs, 3 from the left side+2 from the right side. |
Filler |
---|
Mineral wool |
Bordered openings |
---|
HVAC grille with trimming and with inner U-profile Galvanized |
opening with inner U-profile, RAL, AISI |
Recommended grille types (300x300, 300x400, 300x500, 400x650, 500x650, 600x650). If there are more openings in the panel, and they do not all have the same bordering, it is necessary to describe the bordering as atypical, to specify more details in the notes and to attach a diagram. |
Opening |
---|
no opening |
Required dimensions AxB - the position of the opening must always be specified in a sketch (panels with openings, except for panels with grilles, are quoted as atypical). Maximum opening width is W (panel width in mm) - 300 mm. Maximum number of openings in one panel is 4. Note: With more openings, individual opening dimensions must be separated by means of "," Example: 300x400, 400x400 |
Facing hue and material - standard on the visible side |
---|
according to colour standard |
Facing hue and material - standard on the rear side |
---|