Choose language

E-katalog skupiny BLOCK®

Fire resistant partition panels 102.02/D


Fire resistant partition panels are of the sandwich type, consisting of facing and internal filler. Mineral wool is used as the panel filler. Cable glands can be fitted in the panel for electrical connections.

Fire resistant partitions are made of panels with a fire resistance of EI15/EW30.

The panels are tested in the state testing laboratory with a guaranteed fire resistance class according to standards.

TECHNICAL DATA

Panel type
basic partition panel

Fire resistance
EI15 minutes for panel thickness 60 mm
EI30 minutes for panel thickness 60 mm

Panel thickness

Panel width W
60 mm
W - width in mm according to dimensional range 560 mm, 1190 mm. It is possible to order atypical panel dimensions: min. dimension 300 mm, max. dimension 1190 mm.

Panel height H
1190 mm
560 mm
For EI15/EW30 Height according to standard dimensional range 2550, 2750, 3050 mm. Preferred dimensions 2550, 2750, 3050 mm. Min. dimension 300 mm, max. dimension 4000 mm. Panels of different width must be made as atypical (max. panel width is 1190 mm).

Side end
heightvalue
2550 mm
2750 mm
3050 mm
mmgroove - tongue
mmtongue - tongue
mmgroove - straight
mmstraight - straight
mmvisible HVAC - visible HVAC
mmvisible - tongue
mmvisible - straight
mmvisible HVAC - groove
mmgroove - visible HVAC
mminclined 45°-inclined 45°
mmgroove - visible HVAC
mmstraight - tongue
mmvisible HVAC - tongue
mmtongue - visible HVAC
mmvisible-groove (max. dimension 1150mm)
For EI15/EW30

Bottom end
valueEndurance
basic (tongue)
basic+reinforcement
clasic (tongue)
clasic+reinforcement
groove
atypical

Upper end
valueEndurance
basic (tongue)
basic+reinforcement
clasic (straight)
groove
atypical
clasic+reinforcement

Side reinforcement
valueEndurance
simple reinforcement
no side reinforcement
reinforcement with fireproof linnng
left reinforcement, right reinforcement
reinforced reinforcement
The panel edge with the reinforcement is fitted with an expanding waterstop (foam tape).

Number of cable glands
valueEndurance
no cable gland
2 pcs (1 pc 85 mm from the left- 1 pc 85 mm from the right)
2 pcs (1 pc 250 mm from the left- 1 pc 250 mm from the right)
cable glands from the left, cable glands from the right
Example of designation in the case of multiple cable glands: Orientation and number of cable glands are specified. The first cable gland is 85 mm from the edge. Other cable glands are located 100 mm apart from each other as standard. 3;2 – Total of 5 pcs, 3 from the left side+2 from the right side.For atypical designs, it is necessary to specify A-atypical orientation, number. The dimension must be specified in the notes.

Facing hue and material - standard on the visible side
valueEndurance
Galvanized metal sheet, hue RAL 1015
Galvanized metal sheet, hue RAL 6027
Galvanized metal sheet, hue RAL 9002
Galvanized metal sheet, hue RAL 9016
Stainless steel AISI 304,
Powder coating (Komaxit), hue RAL

Facing hue and material - standard on the rear side
galvanized metal sheet, hue RAL 1015
galvanized metal sheet, hue RAL 6027
galvanized metal sheet, hue RAL 9002
Galvanized metal sheet, hue RAL 9016
Stainless steel AISI 304 FIN 8
Powder coating (Komaxit), hue RAL
Attention: It is necessary to always observe the orientation specified in the diagram of the side end S6.

Atypical design
Type design
Atypical design
Type design
0 - Unique specification out of offered versions
Atypical design
Q - atypical design that cannot be uniquely specified by a code

VATvalue