Choose language

E-katalog skupiny BLOCK®

Circulating unit (CU) to be installed below suspended ceiling or onto movable box 110.04/B


Circulating units are used to supply filtered air to a workplace and to protect the product from ambient contamination.

The design of the circulating unit, together with suitable regulation, provides uniform airflow at the outlet under the unit, with the required speed in the range of 0.3 ÷ 0.45 m.s-1 (when air density ς = 1.2 kg.m3).

The protective effect is enhanced by attaching flexible or fixed screens along the perimeter of the unit.

When installing the circulating unit in areas without a defined class of cleanliness or in an environment with increased dust generation, a pre-filter is mounted at the suction inlet of the unit.

TECHNICAL DATA

Type
circulating unit (CU) to be installed below suspended ceiling or onto movable box
A, B etc. - number of product change

Number of CUs in the laminar field for one controlling device
layout must be documented in a drawing

HEPA filter material and seal
aluminium filter with gel seal
aluminium filter with rubber seal

HEPA filter filtration class
H13 class filtration - H13 class filter is supplied with a height of 69 and 115 mm
H14 class filter is supplied with a height of 91, 105, 115 and 130 mm

HEPA filter dimensions - rubber filters (P)
965x555x69 (H13 only)
965x555x115 (H13, H14)
1180x555x69 (H13 only)
1180x555x115 (H13, H14)

HEPA filter dimensions - gel filters (G)
965x555x80 (H14 only)
965x555x105 (H14 only)
965x555x130 (H14 only)
1180x555x80 (H14 only)
1180x555x105 (H14 only)
1180x555x130 (H14 only)

Outlet design
perforated metal sheet
laminarizator

Fan and motor type
fan 355 with EC motor and integrated electronics, low pressure

Regulation method
manual continuous regulation without feedback
automatic continuous regulation with feedback

Control
control from COP
control from COP and foil keyboard
foil keyboard
control panel with switches
one switch - only for movable laminar boxes

Air velocity indicator
airflow indication - only when controlling via foil keyboard (still under development)
without airflow indication

Lighting - only for the laminarizator version
without lighting
with fluorescent lighting

Suction method
upper suction without pre-filter with cover
upper suction with pre-filter - filtration class G3
bottom suction from room without pre-filter
bottom suction from room with filtration fabric - filtration class G3
suction without pre-filter via HVAC superstructure with upper round neck
suction without pre-filter via HVAC superstructure with upper square neck
suction without pre-filter via HVAC superstructure with side rectangular neck

Shape of laminar flow field
long rectangle connected with short sides
short rectangular array
L-shaped array - screens and covering must be documented in a drawing
rectangle - 1 unit or array connected only with longer sides

Locations of holders of screens and additional covering - also applies to laminar fields (except for L-shapes)
screens at side, front, side side
screens along the whole perimeter of the unit
screens at front, side, rear side
screens at front and left side (front side is longer), same as rear and right side
screens at front and right side (front side is longer), same as rear and left side
screens at front (longer) side
screens and covering not specified

Height of expanded-metal covering to the suspended ceiling
without covering
height of covering (between upper edge of CU and suspended ceiling) must not be less than 200 mm

Screens
without screens
flexible slat screens
fixed screens
flexible antistatic slat screens
fixed antistatic screens

Screen length
length of screens in mm (min. length of screens 250 mm)

Material and surface finish
steel sheet class 11, hue RAL 1015, 5% extra charge
steel sheet class 11, hue RAL 6027, 5% extra charge
steel sheet class 11, hue RAL 9002, 5% extra charge
steel sheet class 11, hue RAL 9016
stainless steel AISI 304 FIN 8