Choose language

E-katalog skupiny BLOCK®

Media panel of type LSK 01/A

JADRO OBOUSTR S DREZEM pozice-2.JPG jadro 002-2.JPG

  1 - Media panel, chapter 206.01
  2 - Worktop, chapter 205.01
  3 - Electrical installations, chapter 207.03
  4 - Liquid and gaseous media outlets, chapter 207.03
  5 - Cabinet for table assembly, chpter 204.02
  6 - Covering to the floor, chapter 204.04
  7 - Worktop, chapter 205.01
  8 - Sink cabinet, chapter 204.01
  9 - Covering to the floor, chapter 204.04
10 - Safety shower, chapter 207.04

 

  • Laboratory table is designed for safe work with chemicals, gases and laboratory instruments.
  • A media panel of type LSK consists of lower and upper installation panel.
  • The upper installation panel can be installed independently from the bottom one.
  • Upper installation panel consists of lateral metal posts and metal removable cartridges.
  • Between the posts of the upper installation panel can be added a shelf and / or lighting.
  • Media installed into a medium panel are selectable. The enlargement is recommended to consult with the seller.
  • Media can be brought from the floor or ceiling. If the supply brought from the ceiling, to the system must be added chimney for achieving of the covering of  distribution.
 

 Variants of implementation


 Dimension series

[ mm ]

 The length of the table

1200,1500, 1650, 1800,2400

 One sided table: 
 (Depth of working surface / depth of the media panel)

800 (600/200),
950 (750/200)

 Double sided table: 
 The depth of the table (working surface  / media panel /
 working surface)

1400 (600/200/600),
1700 (750/200/750)

 The height of working surface

900 (for standing operators),
750 (for seated operators)

 Overall height with a top media panel

1700


 

Optional accessories
- sockets 230V, 400V with the main switch
- socket for PC
- media and water outlets
- eye shower
- vertical bars for the placement of apparatuses
- lighting

TECHNICAL DATA

Type designation
Media panel of type LSK

Combination of installation panels
Upper installation panel
Both instalation panels

Width
widthvalue
1200 mmPanel width
1500 mmPanel width
1650 mmPanel width
1800 mmPanel width
2400 mmPanel width

The height of the bottom panel (working surface)
heightvalue
750 mmThe height of the bottom panel (working surface)
900 mmThe height of the bottom panel (working surface)
The height of the lower installation panel is dependent on the height of the working surface. Therefore, it must be the same as the desired height of the working surface.

Variants of design
Assembling of the table with media panel creates a one-sided table
Assembling of the table with media panel creates an islet table

Table depth
valuedepth
One-sided table depth800 mm
One-sided table depth950 mm
Islet table depth1400 mm
Islet table depth1700 mm

Accessories - supply of media
Supply of media from the ceiling. The supply panel is appended to the assembly
Supply from the floor. The assembly in the basic version

Accessories - shelves
Shelves are not a part of the assembly
The part of assembly is the glass shelf with aluminum frame
The part of assembly is the laminate shelf
The part of assembly is the shelf made from TRESPA material

Accessories - electric socket IP54; 400V
The part of assembly is 1 socket IP 54, 400V
400V socket is not required

Accessories - electric socket IP44; 230V
The part of assembly is 1 socket IP44; 230V
The part of assembly are 2 sockets IP44; 230V
The part of assembly are 3 sockets IP44; 230V
The part of assembly are 4 sockets IP44; 230V
The part of assembly are 5 sockets IP44; 230V
The part of assembly are 6 sockets IP44; 230V
The part of assembly are 7 sockets IP44; 230V
The part of assembly are 8 sockets IP44; 230V
230V socket is not required

Accessories - data drawer
Without data socket
One data socket
Double data socket

Accessories - Lighting
Lighting is not required
Lighting is part of the assembly

Number of media
Outlet for 1 medium
Outlet for 2 media
Outlet for 3 media
Outlet for 4 media
Outlet for 5 media
Outlet for 6 media. Max. for table 1200 mm
Outlet for 7 media. Max. for table 1500 mm
Outlet for 8 media. Max. for table 1800 mm
Offered fittings for gaseous and liquid media are contained in the chapter number 207.