Partition panel with increased thermal resistance 102.06/C
Panels with increased thermal resistance are used for the construction of thermochambers and cold storage boxes.
In areas constructed with these panels, temperature and pressure according to the customer's requirements are maintained.
The whole system of connecting panels to each other and to other components (i.e. door casings, ceiling panels, anchoring to the floor) is designed in such a way as to eliminate thermal bridges and minimise heat transfer.
This panel system also contains other elements for the construction of complete boxes:
- Door with increased thermal resistance (cat. sheet no. 104.06) and
- Ceiling panels (cat. sheet no. 105.06).
TECHNICAL DATA
Panel type |
---|
partition panel with increased thermal resistance |
Panel thickness | |
---|---|
thickness | surface weight |
102 mm | 15.3999996 kg/m2 |
122 mm | 16 kg/m2 |
62 mm | 14.3000002 kg/m2 |
82 mm | 14.8000002 kg/m2 |
Panel width W |
---|
1190 mm |
560 mm |
W - width in mm according to dimensional range 560 mm, 1190 mm.Preferred dimensions: 1190 mm, 560 mm. It is possible to order atypical panel dimensions: min. dimension 300 mm, max. dimension 1190 mm. |
Panel height H |
---|
2400 mm |
2600 mm |
Panel height 2400 and 2600 mm. Min. dimension 300 mm, max. dimension 4000 mm. |
Side end |
---|
groove - tongue |
tongue - tongue |
groove - straight |
straight - straight |
groove - groove |
straight - tongue |
atypical |
Bottom end |
---|
clasic (straight) |
clasic + reinforcement with interrupted thermal bridge (for above-door panels) |
atypical |
Upper end |
---|
clasic (straight) |
atypical |
Side reinforcement |
---|
simple reinforcement with interrupted thermal bridge |
no side reinforcement |
left reinforcement, right reinforcement |
Number of cable glands |
---|
no cable gland |
2 pcs (1 pc 85 mm from the left - 1 pc 85 mm from the right) |
cable glands from the right, cable glands from the left |
Example of designation in the case of multiple cable glands: Orientation and number of cable glands are specified. The first cable gland is 85 mm from the edge. Other cable glands are located 100 mm apart from each other as standard.3;2 – Total of 5 pcs, 3 from the left side+2 from the right side. |
Filler |
---|
Styrofoam IB |
Facing hue and material - standard on the visible side |
---|
Galvanized metal sheet, hue RAL 1015 |
Galvanized metal sheet, hue RAL 6027 |
Galvanized metal sheet, hue RAL 9002 |
Galvanized metal sheet, hue RAL 9016 |
Stainless steel AISI 304 |
Powder coating (Komaxit), hue RAL |
Facing hue and material - standard on the rear side |
---|
Galvanized metal sheet, hue RAL 1015 |
Galvanized metal sheet, hue RAL 6027 |
Galvanized metal sheet, hue RAL 9002 |
Galvanized metal sheet, hue RAL 9016 |
Stainless steel AISI 304 |
Powder coating (Komaxit), hue RAL |
Attention: It is necessary to always observe the orientation specified in the diagram of the side end S5. |
Atypical design |
---|
Type design |
Atypical design |
Type design 0 - Unique specification out of offered versions Atypical design Q - atypical design that cannot be uniquely specified by a code |